Difference between revisions of "Base Information Models"

From UaCapabilities
Jump to: navigation, search
 
Line 3: Line 3:
 
|- style="vertical-align:top;"
 
|- style="vertical-align:top;"
 
|  
 
|  
The OPC UA Object Model provides a consistent, integrated set of NodeClasses for representing object-based information models in the AddressSpace. Objects are represented in terms of their Variables, Events and Methods, and their relationships with other Objects. Information models  may be defined by standards organizations, vendors or end-users.
+
The OPC UA Object Model provides a consistent way for representing object-based information models in the AddressSpace. Information models  may be defined by standards organizations, vendors or end-users.
 
<br>
 
<br>
The "Base Information Models" are specified as part of the OPC UA standard and include Objects that are common in multiple application domains. For example, definitions exist for Alarms, Analog Data, State Machine, and File.
+
A number of "Base Information Models" are specified as part of the OPC UA standard and include Objects that are common in multiple application domains. Definitions exist for alarms, analog and discrete data, historical data and events, and more. Data, alarms and events, and their history can be integrated into a single OPC UA Server. For example, OPC UA Servers are able to represent a temperature transmitter as an Object that is composed of a temperature value, a set of alarm parameters, and a corresponding set of alarm limits.  
<br>Data, Alarms and Events, and their history can be integrated into a single OPC UA Server. For example, OPC UA Servers are able to represent a temperature transmitter as an Object that is composed of a temperature value, a set of alarm parameters, and a corresponding set of alarm limits.  
+
 
|
 
|
 
[[File:UA fw BaseModels.JPG|350px]]
 
[[File:UA fw BaseModels.JPG|350px]]
 
|}
 
|}

Latest revision as of 06:55, 13 February 2015

The OPC UA Object Model provides a consistent way for representing object-based information models in the AddressSpace. Information models may be defined by standards organizations, vendors or end-users.
A number of "Base Information Models" are specified as part of the OPC UA standard and include Objects that are common in multiple application domains. Definitions exist for alarms, analog and discrete data, historical data and events, and more. Data, alarms and events, and their history can be integrated into a single OPC UA Server. For example, OPC UA Servers are able to represent a temperature transmitter as an Object that is composed of a temperature value, a set of alarm parameters, and a corresponding set of alarm limits.

UA fw BaseModels.JPG